Cleaning Program Sequence for Twin Applications

Program Se-
1.
quence with Part-
2.
ing Agent
3.
Atomizer – Over-
4.
view
Cleaning the Gas
Nozzle Tip and
Nozzle Fitting –
Detailed Descrip-
tion
Injecting Parting
The even application of a parting agent has the following advantages:
Agent – Detailed
-
Description
-
50
Welding
Clean the gas nozzle tip and nozzle fitting
Inject parting agent
Welding
NOTE! During the cleaning process, blow out the welding torch with compressed
air via the hosepack. Contamination and surplus parting agent will be removed.
Reduced adhesion of welding spatter
New contamination is prevented
NOTE! Make sure that the gas nozzle does not touch the housing parts of the
cleaning aperture at any time.
NOTE! Make sure that the gas
nozzle does not touch the housing
parts of the cleaning aperture at
any time.
Position the welding torch approx.
1
50 mm (1.97 in.) above the cleaning
aperture and centrically with respect to
the middle of the cleaning aperture
Move the welding torch vertically to the
2
cleaning/injection position
-
See graphic
Trigger the cleaning process and wait
3
for approximately 1 second
Maintain the cleaning position/injection
1
position
-
See graphic
NOTE! During the injection pro-
cess, do not blow out compressed
air through the welding torch.
Inject parting agent into the welding
2
torch for approximately 0.7 seconds