3.6 Wall Enclosure Rough Opening

WARNING: Provide adequate clearance in front of the fireplace for
barrier removal, component access, gas line installation, service
access, etc.
Framing dimensions should allow for wall covering thickness
and fireplace facing materials. If using a hearth, adjust the rough
opening size as necessary to maintain minimum clearance
requirements.
Figure 3.4, Framing Dimensions and Requirements
14 FRAMING
If masonry (optional) is to be used, prepare the foundation
necessary for the full masonry load. A lintel must be used over
the top of the appliance to support the added weight of the
masonry construction above the fireplace.
½
44
"
(1130mm)
41
"
(1051mm)
½
17
"
(445mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
SINGLE VERTICAL HEADER BOARD
IS REQUIRED TO MAINTAIN
CLEARANCES TO COMBUSTIBLES
#BAY-41-LE R.5 July 2019