3.6 Wall Enclosure Rough Opening

WARNING: Provide adequate clearance in front of the fireplace for
barrier removal, component access, gas line installation, service
access, etc.
NOTE: The construction of the fireplace wall enclosure must comply
with local building codes and all clearances as outlined in this manual.
NOTE: Cold air transfer area. The fireplace wall enclosure should be
constructed in a manner to prevent cold air from entering the room
and outside walls should be insulated.
For minimum horizontal vent termination framing, see Section
3.7 Vent Termination Framing on page 15.
If masonry (optional) is to be used, prepare the foundation
necessary for the full masonry load.
If installing optional fan assembly #SP-028, it is easier to install
before unit installation. Please refer to Section 9.3 #SP-028
Optional Fan Kit on page 38.
(940mm)
Figure 3.4, Framing Dimensions
14 FRAMING
37"
41"
(1040mm)
½
15
"
(394mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
3.6.1.1 TV Recess Construction
WARNING: All clearances to venting must be maintained.
Mounting a television above a fireplace has become a common
practice. Television surface temperatures are affected by mantel
depth, ceiling heights, and wall and mantel construction material.
Most television manufacturers specify in their instructions that a
television should not be installed on, near, or above a heat source.
Television location rests solely on the homeowner. It is the home
owner's responsibility that the preferred TV mounting and mantel
design will not exceed the listed maximum operation temperature of
their electronic goods.
Tests performed determined that surface temperatures did not exceed
150°F (66°C) when a 4¼" (108mm) deep recess is constructed above the
fireplace. See illustration below.
Single vertical header board
required to maintain clearances
Ceiling
to combustibles
76"
(1930mm)
TV Recess
Construction
¼
37"
47
(940mm)
(1200mm)
41"
(1044mm)
½
15
"
(393mm)
#SP-41 LE & MV R.6 April 2021
½
4
"
(114mm)
"