Burner Mounting; Gas Supply - Eclipse Linnox SP CCS-LS Installation Manual

Table of Contents

Advertisement

B
M
URNER
OUNTING
G
S
AS
UPPLY
Access
Install the burners so they may be easily accessed for inspection
and maintenance.
Environment
Be sure the burner operating environment matches the original
operating specifications. Check the following items:
Voltage, frequency, and stability of power.
Fuel type and supply pressure.
Adequate fresh and clean combustion air.
Humidity, altitude and temperature of the supply air.
Presence of damaging corrosive gases in the air.
Prevent direct exposure to water.
Because Linnox burners are tailor made for your application
please refer to the attached assembly drawing for information of
mounting plate dimensions and insulation thickness.
The burner mounting plate is provided with:
- sight glass for flame observation
- pressure tap for measuring process pressure
- with or without insulation box (refer to assembly drawing)
- with or without gasket between mounting plate and
installation. (refer to assembly drawing).
Caution:
The burner flame shields can reach a temperature of
1650°F (900°C) at 480°F (250°C) process temperature
before the burner. Measurements should be taken to prevent
excessive thermal load on the process ducting.
The burner should not be used as a support for the incoming gas
supply pipe work. Suitable brackets or hangers should be pro-
vided for this purpose. Care should be taken to ensure that the
incoming gas pipe is adequately sized for the necessary gas flow
and burner pressure (See appropriate data sheet for gas pressure
requirements).
Warning:
Gas inlet pressures must stay within the specified
range. Pressure above the specified range can
damage the ratio regulator.
Pressure below the specified range can impair the
ability of the ratio regulator to control the gas
flow.
Eclipse Linnox Model CCS-LS, Installation Guide 159, 2/20/04
9