Burner Mounting - Eclipse Winnox WX Series Installation Manual

Hide thumbs Also See for Winnox WX Series:
Table of Contents

Advertisement

STALLATIO
ONTINUED
3
45 Minimum
Chamber
insulation
2
igure 3.1 Chamber wall
1
3
Fiber insulation
Chamber
insulation
2
Figure 3.2 Alloy combustion tube
Fiber
insulation
Customer Supplied
Refractory
Combustion Tube
90˚ Hold
2
hamber Wall
ake sure the chamber wall is strong enough to support
the weight of the burner 3. If necessary, reinforce the
mounting area.
ote:
The slots in the combustor must not be covered with
insulation. If necessary, taper the chamber insulation at a
minimum of 45° to provide clearance for the combustor
slots.

Burner Mounting

ount burner to chamber wall using eight (8) customer
supplied nuts and lock washers.
Alloy ombustion Tube
e sure gasket
.
is installed between burner
chamber wall
. ack fiber insulation around the tube to a depth not
beyond the combustor slot position, as illustrated.
aution:
Placing insulation over combustor slots will impede burner
performance and decrease combustor life
o gasket is supplied or required between burner and
.
combustor.
efractory Plug
hen using the refractory plug the customer must provide a
refractory combustion tube. The customer is responsible for
supplying all refractory materials for combustion tube field
installation as follows:
.
nstall the chosen refractory realizing that it is essential
that:

the combustion tube dimensions are held as given on
Eclipse drawings.

the inside diameter of the combustion tube is
concentric with the refractory plug.
.
upport refractory tube according to the refractory
supplier’s recommendations. The alloy anchors should be
coated with bitumastic wherever they are used.
fter the burner and refractory have been installed, a
.
proper curing schedule should be followed according to
refractory supplier’s recommendations.
clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05
and