nstallation Guide o. 111, 8/26/05 Winnox Burners WX Series Version 1.00...
Page 2
RR NTY parts and Eclipse, Inc. will not be liable for any other injury, loss, damage or expenses, whether direct or consequential, including but not limited to loss of use, income of or damage to material arising in connection with the sale, installation, use of, inability to use or the repair or replacement of Eclipse...
Used with Data Sheet to design burner system Winnox Price List No. 111 Used to order burners EFE 825 (Combustion Engineering Guide) ELATED OCUMENTS Eclipse Bulletins and Info Guides: 684, 710, 732, 742, 756, 760, 930 clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 4
Indicates an important part of the text. Read thoroughly. f you need help, contact your local Eclipse Combustion representative. Y ou can also contact Eclipse Combustion at any of the addresses listed on the back of this document. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
direct spark ignition multiple fuel capability A wide variety of options and configurations are available due to the modular design of the burner. igure 1.1 The Winnox Burner clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Read the entire this manual and all related documents before attempting to start this system. If you do not understand any part of the information contained in this manual, contact your local Eclipse representative or Eclipse Combustion before continuing. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 8
Eclipse Combustion only. All PLAC M NT Eclipse Combustion approved, customer supplied valves or switches should carry UL, FM, CSA, CGA, and/or CE approval, where applicable. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
EN 746-2 Electrical wiring All electrical wiring must comply with all applicable local codes and/or standards, which may include: NFPA Standard 70 ANS -C11981 EN 746-2 clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Information on the E standards, and where to get the standards is available from: Comité Européen de ormalisation Strassartstraat 36 B-1050 Brussels Comité Européen de ormalisation Electronique Strassartstraat 36 B-1050 Brussels clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 11
Position these Combustor bolts to match the clearance holes (C) on the burner Chamber wall mounting flange. Refer to the appropriate Winnox data sheet. “C” clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
The alloy anchors should be coated with bitumastic wherever they are used. fter the burner and refractory have been installed, a proper curing schedule should be followed according to refractory suppliers recommendations. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 13
Winnox Design Guide No. 111 using the following guidelines: Locate the start gas solenoids close to the burner . The gas must reach the burner during the trial for ignition period. Minimize piping elbows. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 14
Be sure all valves are installed in the proper location and correctly oriented relative to the flow direction. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Close all the burner gas valves, manual and automatic. Try to ignite the burner; be sure the flame monitoring system indicates a flame failure. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 16
If it doesnt, refer to the actuators literature for instructions on how to reverse the direction. Closed Open in this direction only igure 4.1 Air BV open direction clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 17
Troubleshooting and Maintenance, in this document. BV shaft shown Return the control motor to the low fire position. in closed position Close the pressure taps. igure 4.4 Air BV Shaft clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 18
V erify pressure is within the range specified on the Data Sheet for your burner. erify repeatability of ignition and low fire flame signal. lose all pressure taps. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 19
V erify pressure is within the range specified on the Data Sheet for your burner. erify repeatability of ignition and low fire flame signal. Close all pressure taps. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 20
Turn the burner off and repeat the ignition sequence. erify low fire and stable flame signal are repeated. 9. Close all pressure taps. igure 4.8 Manual BV adjustment clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 21
Data Sheet. . If required gas flow cannot be achieved, refer to Chapter 5, Maintenance and T roubleshooting for guidance. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 22
250°F (121° ). This will prevent hot Figure 4.10 Verify pressure settings gases from back flowing into the burner and blower causing damage to the burner. top the burner. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
T est the manual gas shut off cocks for proper operation. Clean and/or replace the combustion air blower filter. nspect and clean the combustion air blower rotor. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 24
The combustor can be inspected only by removing the burner from the chamber wall or entering the chamber. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 25
Check the output from the flame safeguard. Open manual gas cock. Not enough gas: Adjust the ratio regulator to the atio regulator is incorrectly proper setting. set. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 26
The burner cannot achieve full ir filter is blocked. Clean or replace the air filter. capacity. as pressure going into the Adjust the gas pressure. ratio regulator is too low. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...
Page 27
Be sure the main power to the ain power is off. system is switched to the on position. clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05...