Full wire speed switching
At 100 Mbps
148810
84459
45290
23496
11973
9615
8127
Note
The following applies to IE Switches X-300:
The number of IE Switches X-300 connected in a line influences the frame delay time. When
a frame passes through the switch, this is delayed by the Store&Forward function of the
IE Switch X-300 by the following values:
● at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps)
● at 1500 bytes frame length: Delay of approx. 130 microseconds (at 100 Mbps)
This means, the more IE Switches X-300 a frame runs through, the higher the frame delay.
PRP compatibility
Device variant
XR324-4M PoE
XR324-4M PoE TS
* Information about the firmware version (V) as of which PRP is supported.
Note
For a device to be used in PRP networks, it must be able to process a frame length of at least
1528 bytes (Jumbo Frames). This value is the maximum frame length including VLAN tag of
1522 bytes plus the length of the PRP trailer of 6 bytes. The following table shows the version
as of which the devices are PRP-compatible.
8.9

MM900 technical specifications

Note
Validity of the technical specifications
All the technical specifications described in this section that are not specific to a product
version, apply to the MM900 media module.
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24
Number of frames per second
At 1000 Mbps
1488095
844595
452899
234962
119732
96154
81274
8.9 MM900 technical specifications
At a frame length of
64 bytes
128 bytes
256 bytes
512 bytes
1024 bytes
1280 bytes
1518 bytes
As of version *
V3.7.0
V3.7.x
Technical specifications
201