Installation
5.4 Installing a switch
5.4.6

19" rack mounting - XR-300M EEC product group

Danger of injury by falling objects
If you do not use the supplied mounting brackets for 19"rack installation, it is not possible to
install the device correctly.
Use only the supplied mounting brackets.
There are several ways of fixing the mounting brackets depending on the mounting position
required.
19" rack mounting
19" rack mounting is possible for all rack devices identified by (XR).
Refer to the technical specifications, Installation options table for each product group. The rack
device is installed using two mounting brackets fitted to the front. After fitting the two mounting
brackets, the rack device can then be installed in a 19" cabinet.
NOTICE
Do not cover the ventilation grilles
During installation, select a mounting position so that the ventilation grilles are always free to
achieve adequate cooling. With normal orientation, the ventilation grilles are on the top,
bottom and sides of the housing.
If you install more than one rack device, make sure that the permitted ambient conditions are
met for all devices in the rack.
Minimum clearances
If you install the IE Switch in rack devices without forced ventilation or cooling, minimum
clearances must be maintained to neighboring devices or the wall of the enclosure. By keeping
to the minimum clearances, there is then an adequate stream of air for heat dissipation during
operation. Keep to the following minimum clearances to neighboring devices.
Table 5-4
Minimum clearance to devices below the switch
Minimum clearance to devices above the switch
Minimum clearance between two SCALANCE XR-300 EEC at an am‐
bient temperature up to 70 °C without external ventilation
Minimum clearance between two SCALANCE XR-300 EEC at an am‐
bient temperature up to 60 °C without external ventilation
110
CAUTION
Minimum clearances for installation in rack devices
100 mm
100 mm
100 mm
45 mm (1 height unit)
Operating Instructions, 11/2019, A5E01113043-24