Siemens SCALANCE X-300 Series Operating Instructions Manual page 175

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300 Series:
Table of Contents

Advertisement

Table 8-41
Strain withstood / category (standard) Test conditions
Vibration
(IEC 60068-2-6)
Vibration
(IEEE1613 Class V.S.2)
Shock
(IEC 60068-2-27)
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24
Mechanical stability
8.5 Technical specifications for X-300EEC
Frequency range 10 Hz to 150 Hz:
● Transit frequency: 58 Hz to 60 Hz
● Peak value of the displacement [mm] below the transit
frequency: 0.075
● Peak value of the acceleration [g] above the transit
frequency: 1
● Number of cycles per axis: 20
Frequency range 5 Hz to 150 Hz:
● Transit frequency: 8.4 Hz
● Peak value of the displacement [mm] below the transit
frequency: 3.5
● Peak value of the acceleration [g] above the transit
frequency: 1
● Number of cycles per axis: 10
● Octaves / min: 1
Frequency range 2 Hz to 100 Hz:
● Frequency range: 2 Hz to 100 Hz
● Transit frequency: 13.2 Hz
● Peak value of the displacement [mm] below the transit
frequency:1
● Peak value of the acceleration [g] above the transit
frequency: 0.7
● Number of cycles per
● Velocity: <10 mm/s
● Frequency: 1 to 150 Hz
● Acceleration: 15 g
● Duration of the pulse: 11 ms
● Number of shocks per direction: 3
Technical specifications
175