5
Commissioning
Î Connect the device to the mains.
The controller runs an initialisation phase.
When the controller is commissioned or when it is reset, it will run a commission-
ing menu. The commissioning menu leads the user through the most important
adjustment channels needed for operating the system.
Operation
3
Adjustment mode
1
Changing a value
2
Confirming a value
3
1
to the next
parameter
2
48
1
forwards (+)
Ⓢ (selection /
3
adjustment mode)
2 backwards (-)
flashing
flashing
not flashing
Commissioning
1. Language
Î Adjust the desired menu language.
LANG
Language selection
Selection: dE, En, Fr, ES, It
Factory setting: dE
2. Temperature unit
Î Adjust the desired unit.
UNIT
Temperature unit
Selection: °F, °C
Factory setting: °C
3. Time
Î Adjust the clock time.
First of all adjust the hours, then the minutes.
TIME
Real time clock
4. Arrangement
Î Adjust the desired system.
For a detailed description of the systems to choose
from, see page 8.
Arr
System selection
Adjustment range: 1 ... 10
Factory setting: 1
If the system layout selection is changed later on, any
previous adjustments which have been made in the
other channels will be lost. Therefore, changing the sys-
tem is always followed by a security enquiry.