Emerson Micro Motion LF Series Installation Manual page 64

Flowmeter
Table of Contents

Advertisement

I/O Wiring – DIN CIO Transmitters
Figure 10-6
Note: See Figure 10-15 for recommended
resistor versus supply voltage.
Excessive current will damage the transmitter.
Do not exceed 30 VDC input. Terminal current must be less than 500 mA.
Figure 10-7
Note: Refer to Figure 10-14 for output
voltage versus load resistance.
58
Frequency output wiring – Terminals 23 & 24 (Channel B) – External power
3–30 VDC
+
Counter
Frequency output wiring – Terminals 31 & 32 (Channel C) – Internal power
Counter
Output voltage level is +15 VDC ±3%
with high resistance load.
000042
Pull-up resistor
CAUTION
000042
LF-Series Flowmeters: Sensor/Transmitter Installation
+
+