Lf-Series Transmitter Specifications; Output Options And Output Option Codes - Emerson Micro Motion LF Series Installation Manual

Flowmeter
Table of Contents

Advertisement

Dimensions and Specifications
Table A-4
Hazardous area classifications
Approvals agency
(1)
CSA
(2)
ATEX
(1) CSA is a Canadian approvals agency that provides approvals accepted both in the U.S.A. and in Canada.
(2) ATEX is a European directive.
Table A-5
Materials of construction
Component
Wetted parts
Process seals
Housing
®
(1) Viton
is a registered trademark of DuPont Performance Elastomers.
Table A-6
Physical specifications
Weight
Fittings
A.3

LF-Series transmitter specifications

A.3.1

Output options and output option codes

Table A-7
Transmitter outputs
Outputs
1 mA output, 1 frequency/pulse output
2 mA outputs, 1 frequency/pulse output
(configurable)
F
fieldbus
OUNDATION
Profibus-PA
LF-Series Flowmeters: Sensor/Transmitter Installation
Classification
Class I Division 2 Groups A, B, C, D
Class II Division 2 Groups F and G
Class III Division 2
II 3 G EEx nA II T4
II 3 D IP65 T135°C
Material
316L stainless steel, 316L VAR and high alloy ferritic stainless steel 17-7PH
®
(1)
Viton
fluoroelastomer
, Buna, Kalrez, or EPDM
Epoxy-painted aluminum
3.5 lb (1,6 kg)
See product data sheet
FM transmitters
Output option codes 1 and 3 (FM AN)
Output option code 4 (FM CIO)
Output option code 6 (FM FB)
Output option code 7 (FM PB)
DIN transmitters
Output option code 2 (DIN AN)
Output option code 5 (DIN CIO)
(Not available)
(Not available)
71

Advertisement

Table of Contents
loading

Table of Contents