Refer to the
measurements with your Keysight M9391A PXIe Vector Signal Analyzer.
Parameter Control and Input Extensions
The M9391 hardware extension for Keysight 89600 VSA software enables the VSA
software to set the following parameters:
Extensions
Input extensions are hardware configuration and setup parameters that apply to
the Keysight 89600 VSA software with M9391A. To modify a hardware parameter,
open the input extension dialog (
and specify the value. For True/False values, a selected check box sets the value to
True. A cleared check box sets the value to False.
The following input extensions are instrument level (coupled across channels):
The following input extensions are channel dependent (not coupled across
channels):
Keysight M9391A PXIe Signal Analyzer & M9381A PXIe Vector Signal Generator 1 MHz to 3 GHz or 6 GHz
Auto Calibrate takes approximately 4 minutes per channel. Therefore, you
should turn
Auto Calibrate
check box) immediately after selecting a hardware configuration with multiple
M9391A channels.
Keysight 89600 VSA Software
Expected Input Power (Range)
Center Frequency
Bandwidth
Acquisition Time
Trigger Style (Free Run, External, IF Mag)
Trigger Delay
Trigger Slope
Trigger Level
Conversion (to set mixer conversion type) {Auto, Image Protect,
SingleHighSide, SingleLowSide}
External Trigger Termination {HighImpedance, 50 Ohm}
External TTL Trigger Source (PXI_TRIG0...PXI_TRIG7)
Magnitude Trigger Bandwidth {Normal, Wideband}
Phase Noise Optimization {Normal, BestWideOffset}
Time Average Count
Time Average Period (Seconds)
ADC Dither (to improve small signal performance) {On, Off}
Baseband Delay (seconds)
off (
Utilities > Calibrations,
for further details about making
Input > Extensions
tab), click the parameter name
clear the
Auto Calibrate
104