Summary of Contents for Keysight Technologies M9391A
Page 1
Keysight Technologies M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz Specifications Guide...
Page 2
DFARS and are set forth speciically agreement and written consent from chassis, controllers, modules, etc.) perfor- in writing elsewhere in this EULA. Keysight Technologies, Inc. as governed by mance, safety, or regulatory compliance, Keysight shall be under no obligation United States and international copyright unless specifically stated.
Page 3
in the specifications and operating informa- – Service personnel are trained to work The responsible body must ensure that on live circuits, perform safe installa- tion, and as shown on the instrument or test operators are prevented access and/or tions, and repair products. Only properly fixture panels, or switching card.
Page 4
To prevent electrical shock, disconnect A 급 기기 ( 업무용 방송통신기자재 ) the Keysight Technologies instrument from 이 기기는 업무용 (A 급 ) 전자파적합 mains before cleaning. Use a dry cloth or 기기로서 판 매자 또는 사용자는 이 점...
How to use this document This document contains technical specifications for all versions of the M9391A PXIe Vector Signal Analyzer. Specifications published in the datasheet only apply to the current manufactur- ing version of the equipment. If a specification only applies to a certain manufacturing version of the equipment, it is indicated in this document.
6 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Definitions for specifications Characteristics describe product performance that is useful in the application of the product, but that is not covered by the Temperatures referred to in this document are defined as follows: product warranty.
7 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Frequency Frequency range and resolution Option F03 1 MHz to 3 GHz Option F06 1 MHz to 6 GHz Tuning resolution 0.001 Hz...
Page 8
8 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Frequency (continued) Frequency reference (M9300A PXIe frequency reference module) Reference outputs 100 MHz Out (Out 1 through Out 5) Amplitude ≥...
9 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Amplitude Input level Max safe average total power +30 dBm (1 W) Max DC voltage 25 Vdc...
Page 10
010 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 GHz or 6 GHz - Data Sheet Technical Specifications and Characteristics Amplitude (continued) Amplitude repeatability and linearity Input signal relative to expected input level setting Specification Repeatability <0.05 dB, nominal...
Page 11
11 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Amplitude (continued) IF bandwidth filter switching uncertainty Specification Typical Nominal ±0.4 dB ±0.15 dB ±0.09 dB Expected input level switching uncertainty...
12 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Dynamic range Displayed average noise level (DANL) Conversion type Frequency Specification Nominal Pre−amp OFF Image protect < 100 MHz −145 dBm/Hz...
Page 13
13 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Dynamic range (continued) Second harmonic distortion (SHI) Conversion type: image protect Frequency SHI, nominal Distortion, nominal – 45 dBc Pre-amp OFF ≤...
Page 14
14 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Dynamic range (continued) Nominal Dynamic Range at 2 GHz Pre-Amp Off, Image Protect -100 -110 -120 -130...
18 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Measurement speed IQ data capture Nominal Large block (50 MSamples) 1.5 s Transferred in 100 kSa or 1 MSa blocks...
Page 19
19 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Format Specific measurement (continued) W−CDMA Parameters Typical Nominal 51, 52 Residual EVM 2 GHz, 1 DPCH, 1 carrier 0.5%...
Page 20
20 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Format specific measurement (continued) Spectral Emissions Limit Figure 7. WLAN 802.11ac SEM at 5.8 GHz, 80 MHz bandwidth.
Page 21
59. Synthesizer PLL mode set to PLL mode normal. 60. MIMO configurations require M9391A instrument driver version 1.1 or greater, with each channel configured with its own independent synthesizer. Sharing a single synthesizer will degrade EVM performance approximately 1 dB.
22 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics Environmental and physical specifications Operating Individual module temp 25 to 75 °C as reported by the module and environment temp of 0 to 55 °C...
23 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide Technical Specifications and Characteristics System requirements Topic Windows 7 requirements Operating systems Windows 7 (32-bit and 64-bit) Processor speed 1 GHz 32-bit (x86), 1 GHz 64-bit (x64)
Page 24
24 | Keysight | M9391A PXIe Vector Signal Analyzer 1 MHz to 3 or 6 GHz - Specifications Guide For more information on Keysight For more information on Keysight myKeysight Technologies’ products, applications or Technologies’ products, applications or www.keysight.com/find/mykeysight services, please contact your local Keysight services, please contact your local Keysight A personalized view into the information most relevant to you.
Need help?
Do you have a question about the M9391A and is the answer not in the manual?
Questions and answers