Keysight Technologies M9203A Configuration And Measurement Instructions
Keysight Technologies M9203A Configuration And Measurement Instructions

Keysight Technologies M9203A Configuration And Measurement Instructions

High-speed digitizers hardware extension of 89600 vsa software

Advertisement

Quick Links

Keysight M9203A High-Speed
Digitizers Hardware Extension of
89600 VSA Software
Configuration and
Measurement Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Keysight Technologies M9203A

  • Page 1 Configuration and Measurement Instructions Keysight M9203A High-Speed Digitizers Hardware Extension of 89600 VSA Software...
  • Page 2: Copyright Notice

    KEYSIGHT TECHNOLOGIES DOES NOT without prior agreement and written and the DFARS and are set forth WARRANT THIRD-PARTY SYSTEM-LEVEL consent from Keysight Technologies, Inc. specifically in writing elsewhere in the (COMBINATION OF CHASSIS, as governed by United States and EULA. Keysight shall be under no CONTROLLERS, MODULES, ETC.)
  • Page 3 Introduction Introduction The 89600 VSA software (89601B) supports the Keysight M9203A High-Speed Digitizer. This VSA measurement hardware configuration offers broadband vector signal analyzer capabilities. The maximum analysis bandwidth is model dependent. Model Option Maximum Span (Analysis Bandwidth) M9203A -SR2 625 MHz (1.25 GHz in interleaved mode) The present document aims to describe how to configure and use VSA software with Keysight High-Speed Digitizers.
  • Page 4: Software Installation

    The latest VSA (89601B) software version can be downloaded from http://www.keysight.com/find/VSA. The support of M9203A digitizer also requires installing a plugin so that VSA can recognize this hardware. This MD2 Hardware Extension for VSA software can be accessed from following link: MD2 Digitizers Hardware Extension for 89600 VSA Software or found from M9203A product page (www.keysight.com/find/M9203A) >...
  • Page 5 Keysight MD2 Digitizers Extension of Keysight 89600 VSA. And select Change. The InstallShield Wizard opens. Select Repair and click Next. This automatically installs the MD2 Digitizers Hardware Extension in the new 89600 VSA Software version. M9203A Hardware Extension of 89600 VSA Software...
  • Page 6 C:\Program Files\Keysight\MD2\89600 VSA Connectivity\MD2Digitizers\89600VSAIntegration.exe (or using your installation path) Follow the installation process. Click OK. The installation of the MD2 Digitizers Hardware Extension in the new 89600 VSA Software version is now completed. M9203A Hardware Extension of 89600 VSA Software...
  • Page 7 89600 VSA Software Configuration Configuring the 89600 VSA software application to use the digitizer hardware Create a configuration for Keysight M9203A digitizer 1. Start the 89600 VSA software application. 2. Configure the digitizer as the VSA measurement input by creating an 'Analyzer...
  • Page 8 Click OK to close the 'New Hardware Configuration' dialog (6). g. Before closing the 'Hardware Configurations' dialog, use the Current Analyzer Configuration drop-down to select the newly created as the current item ( Digitizer1 in the exemple below). M9203A Hardware Extension of 89600 VSA Software...
  • Page 9 External Clock (page 12) Enable interleaving: See Interleaved Mode (page 11) Error on overrange: This feature is not supported with M9203A digitizer. External clock frequency: See External Clock (page 12) Force Software DDC: This option is effective only if your product has been ordered with the -DDC option (Digital Down-Conversion).
  • Page 10: Multi-Channel Measurements

    When using the Keysight High Speed Digitizers in VSA configuration, the digitizer forms the measurement front-end data acquisition hardware for the 89600 VSA software. The M9203A digitizer supports single channel I+jQ, and cross channel measurement configurations. M9203A Hardware Extension of 89600 VSA Software...
  • Page 11 0 - 1.6 GHz 1.6 GS/s leaved) -SR2 Interleaved 0 - 1.4 GHz 3.2 GS/s For best measurement fidelity, you should ensure that the signal center frequency + (analog bandwidth/2) does not cross the Nyquist frequency. M9203A Hardware Extension of 89600 VSA Software...
  • Page 12: External Clock

    External clock frequency value to bring up the editing window. You may then set the value of the external clock frequency being applied. As shown below: M9203A Hardware Extension of 89600 VSA Software...
  • Page 13 Measurement Setup Parameters This section provides measurement and parameter setup information which are specific to the 89600 VSA software when used along with the M9203A High Speed Digitizer. This information can help you to properly setup the VSA in this hardware configuration to make measurements using your digitizer.
  • Page 14 Maximum Span = Min( Sample Rate / 2.56 ; Analog Bandwidth) The analog bandwidth depends on the digitizer, the option (-Fxx) and interleaving mode (see product datasheet for details). Maximum span depends also on the digitizer sampling rate. M9203A Hardware Extension of 89600 VSA Software...
  • Page 15 Slope: available for External, Magnitude and Channel On Segmented Capture mode the free run triggered is not supported. (Segmented Capture feature may be accessed via the MeasSetup > Time menu) -DDC option is required for Magnitude triggering. M9203A Hardware Extension of 89600 VSA Software...
  • Page 16 Setup Save/Recall: The digitizer state is not saved when the VSA application is closed. When a setup is recalled into the VSA, the digitizer state is set appropriately based on the recalled VSA setup. M9203A Hardware Extension of 89600 VSA Software...

Table of Contents