Keysight M9710A High-Speed
Digitizers Hardware Extension of
89600 VSA Software
Configuration and
Measurement Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Keysight Technologies M9710A

  • Page 1 Configuration and Measurement Instructions Keysight M9710A High-Speed Digitizers Hardware Extension of 89600 VSA Software...
  • Page 2: Copyright Notice

    KEYSIGHT TECHNOLOGIES DOES NOT without prior agreement and written and the DFARS and are set forth WARRANT THIRD-PARTY SYSTEM-LEVEL consent from Keysight Technologies, Inc. specifically in writing elsewhere in the (COMBINATION OF CHASSIS, as governed by United States and EULA. Keysight shall be under no CONTROLLERS, MODULES, ETC.)
  • Page 3 Introduction Introduction The 89600 VSA software (89601B) supports the Keysight M9710A High-Speed Digitizer. This VSA measurement hardware configuration offers broadband vector signal analyzer capabilities. The maximum analysis bandwidth is model dependent. Model Option Maximum Span (Analysis Bandwidth) M9710A -SR4 1.953 GHz (2.5 GHz in interleaved mode) The present document aims to describe how to configure and use VSA software with Keysight High-Speed Digitizers.
  • Page 4: Software Installation

    The latest VSA (89601B) software version can be downloaded from http://www.keysight.com/find/VSA. The support of M9710A digitizer also requires installing a plugin so that VSA can recognize this hardware. This MD2 Hardware Extension for VSA software can be accessed from following link: MD2 Digitizers Hardware Extension for 89600 VSA Software or found from M9710A product page (www.keysight.com/find/M9710A) >...
  • Page 5 Keysight MD2 Digitizers Extension of Keysight 89600 VSA. And select Change. The InstallShield Wizard opens. Select Repair and click Next. This automatically installs the MD2 Digitizers Hardware Extension in the new 89600 VSA Software version. M9710A Hardware Extension of 89600 VSA Software...
  • Page 6 C:\Program Files\Keysight\MD2\89600 VSA Connectivity\MD2Digitizers\89600VSAIntegration.exe (or using your installation path) Follow the installation process. Click OK. The installation of the MD2 Digitizers Hardware Extension in the new 89600 VSA Software version is now completed. M9710A Hardware Extension of 89600 VSA Software...
  • Page 7 89600 VSA Software Configuration Configuring the 89600 VSA software application to use the digitizer hardware Create a configuration for Keysight M9710A digitizer 1. Start the 89600 VSA software application. 2. Configure the digitizer as the VSA measurement input by creating an 'Analyzer...
  • Page 8 Click OK to close the 'New Hardware Configuration' dialog (6). g. Before closing the 'Hardware Configurations' dialog, use the Current Analyzer Configuration drop-down to select the newly created as the current item ( Digitizer1 in the exemple below). M9710A Hardware Extension of 89600 VSA Software...
  • Page 9 Enable interleaving: See Interleaved Mode (page 11) Error on overrange: By default, if an overrange condition occurs on the ADC inputs, the driver returns an error. Disabling this option disables the overrange detection. M9710A Hardware Extension of 89600 VSA Software...
  • Page 10: Multi-Channel Measurements

    When using the Keysight High Speed Digitizers in VSA configuration, the digitizer forms the measurement front-end data acquisition hardware for the 89600 VSA software. The M9710A digitizer supports single channel I+jQ, and cross channel measurement configurations. The M9710A also supports 2 channels Dual I + jQ.
  • Page 11 0 - 2.5 GHz 5 GS/s leaved) -SR4 Interleaved 0 - 2.5 GHz 10 GS/s For best measurement fidelity, you should ensure that the signal center frequency + (analog bandwidth/2) does not cross the Nyquist frequency. M9710A Hardware Extension of 89600 VSA Software...
  • Page 12: External Clock

    External clock frequency value to bring up the editing window. You may then set the value of the external clock frequency being applied. As shown below: M9710A Hardware Extension of 89600 VSA Software...
  • Page 13 Measurement Setup Parameters This section provides measurement and parameter setup information which are specific to the 89600 VSA software when used along with the M9710A High Speed Digitizer. This information can help you to properly setup the VSA in this hardware configuration to make measurements using your digitizer.
  • Page 14 Model Option Maximum Span (Analysis Bandwidth) -SR4 -F25 1.953 GHz (2.5 GHz in interleaved mode) The maximum span is obtained with following formula: Maximum Span = Min( Sample Rate / 2.56 ; Analog Bandwidth) M9710A Hardware Extension of 89600 VSA Software...
  • Page 15 Main Time Length: Standard VSA parameter. Can be configured by user. Maximum value depends on the memory option of your module. When using a M9710A with memory option -M80, note that the maximum number of sample is limited to 2'147'483'647.
  • Page 16 Setup Save/Recall: The digitizer state is not saved when the VSA application is closed. When a setup is recalled into the VSA, the digitizer state is set appropriately based on the recalled VSA setup. M9710A Hardware Extension of 89600 VSA Software...