7. Enter the TCP slave port number "503" in the "Port" text box of the "TCP / IP
Server" area.
8. Other parameters remain the default, click "OK".
9. Run the "mbpoll.exe" software, click "Setup> Read / Write Definition".
10. Enter "3" in the "Slave ID" text box.
11. Other parameters remain the default, click "OK".
12. Click " Connection > Connection Setup ".
13. Click the "Connection" drop-down list box and select "serial port".
14. In the "Serial Settings" option box, configure serial port information such as serial
number, baud rate, data bit, parity bit and stop bit.
15. Select the "ASCII" mode in the "Mode" option.
16. Other parameters remain the default, click "OK".