Fitting Probes - Elcometer 456 3 Operating Instructions Manual

Coating thickness gauge, basic models
Table of Contents

Advertisement

R

2.3 FITTING PROBES

(separate versions only)
To ensure correct transfer of data from the
probe and detection of the new probe, the
gauge must be switched off when
separate probes are fitted.
A probe must be calibrated once it has been
fitted - see "Calibration adjustment" on page 22.
To fit the probe
Align connector keyway and
push in direction shown. The
connector locks automatically.
Note: The design of the probe
connector
allows
movement between the probe
and the gauge. This is intentional
and
does
not
measurement performance.
8
some
affect
To release the probe
Grasp knurled section and pull
gently away from the gauge. The
connection will unlock and the
probe will release.
To fit the PINIP™
Twist the PINIP™ until the
connector locates. Taking
care not to cross the
threads, lock the probe by
turning the locking ring
1½ times clockwise, or
until tight.