The following features are added to the MENU
when EXTENDED MENU is active:
PRINT/OUTPUT
Outputs individual readings or a statistical summary
via the RS232 interface.
To use this function, first setup using:
MENU/SETUP/OUTPUT - see "OUTPUT:" on
page 20.
If no printers have been setup, PRINT/OUTPUT will
display a NOT AVAILABLE message.
DELETE
Deletes last reading only. Gauge displays ARE
YOU SURE? (Figure 16).
Figure 16. Delete last reading confirmation
Press NO softkey to include reading in statistical
summary or YES softkey to delete reading.
screen
If there is no reading to delete, the gauge displays:
Figure 17. Delete last reading not available
Press OK to return to Delete menu.
CAL METHOD
Allows selection of calibration method from list of
options - see "Calibration method" on page 22 for
more details.
SETUP
Used to select, change or activate gauge features:
STATISTICS: Activates simple statistics feature.
Display - see "Display" on page 32.
Set NDFT - see "Set NDFT" on page 31
Select stats - see "Select stats" on page 31.
Softkey enabled - switches STATS softkey on/off.
screen
R
19