IC-KP-B6*
Communication in "IRI-B6" mode and "IVI-B6" mode
Control Word
Bit
0 ... 7
8 ... 15
16
17
18 ... 23
24 ... 31
Configure read range
1. Enable the password mode (command set password mode)
2. Write into the Control Word the "beginning of the reading area" = 03h and
"end of the reading area" = 03h with the commands single write configuration
or enhanced buffered write configuration
3. Disable the password mode (command set password mode)
word count reading 00h.
6
Meaning
Beginning of reading area
End of read area
Password mode on / off
Mode "Read-after-Write" on / off
freely usable
freely usable
You can check the data area with address information reading 0000h and
Byte
0
1
2
3