IC-KP-B6*
Communication in "IVI-B6" mode
Word 1
Status/execution counter/head number
-
0
or
0
or
0
Head number (K3 ... K1)
Execution counter (A4 ... A1)
Status (S4 ... S1)
or
or
24
K3
K2
K1
A4
A3
0
0
1
0
0
0
0
1
0
0
0
0
1
0
0
001b
0001b
0101b
0110b
0000b
A2
A1
-
-
-
0
1
0
0
0
0
1
0
0
0
0
1
0
0
0
Read with head 2
Executed once
Read or write error
Hardware error
Command executed without error
-
S4
S3
S2
S1
0
0
1
0
1
0
0
1
1
0
0
0
0
0
0