Voltage Class
Model
CIMR-J7A!!!!
Status Indicator LED
Digital Operator
Terminals
Wiring Distance between
Inverter and Motor
Enclosure
Cooling Method
Ambient Temperature
Humidity
Storage Temperature*
Location
Elevation
Vibration
* Temperature during shipping (for short period)
† If the wiring distance between inverter and motor is long, reduce the inverter carrier
frequency.
For details, refer to "Reducing motor noise or leakage current (n46)" on page 79.
20
All manuals and user guides at all-guides.com
3-phase
40P2
40P4
RUN and ALARM provided as standard LEDs
Available to monitor frequency reference, output
frequency, output current. 3 character, 7 segment
LED display.
Main circuit: screw terminals
Control circuit: plug-in screw terminal
328ft (100m) or less†
Open chassis or enclosed wall-mounted
Cooling fan is provided for 200V, 0.75kW (3-/single
phase), 200V, 0.75kW (1.5HP), others are self-
cooling
Open chassis: -10 to +50°C (14 to 122°F)
95% RH or less (non-condensing)
-20 to 60°F (-4 to +140°C)
Indoor (free from corrosive gases or dust)
3280ft (1000m) or less
Up to 9.8m / S
(0.2G) at less than 20 to 50Hz
400V 3-phase
40P7
41P5
42P2
(not frozen)
2
(1G) at less than 20Hz, up to 2m / S
43P7
2