• Monitoring
Following items can be monitored by U-parameters
Parameter
Name
No.
Frequency reference
U-01
(FREF)
Output frequency
U-02
(FOUT)
Output current
U-03
(IOUT)
U-04
Output voltage
U-05
DC voltage
U-06
Input terminal status
U-07
Output terminal status
U-09
Fault history
U-10
Software No.
U-15
Data reception error
Frequency reference can be monitored.
Hz
(Same as FREF)
Output frequency can be monitored.
Hz
(Same as FOUT)
Output current can be monitored.
AMP
(Same as IOUT)
V
Output voltage can be monitored.
V
Main circuit DC bus voltage can be monitored.
Input terminal status of control circuit terminals can be
—
monitored.
Output terminal status of control circuit terminals can
—
be monitored.
—
Last four fault history is displayed.
—
Software No. can be checked.
Contents of MEMOBUS communications data
—
reception error can be checked. (contents of
transmission register No. 003DH are the same)
Description