YASKAWA VS MINI J7 Series Instruction Manual page 32

Compact general-purpose inverter (voltage vector control)
Hide thumbs Also See for VS MINI J7 Series:
Table of Contents

Advertisement

Register
No. for
No.
Name
Trans-
mission
70
0146H
Slave address
71
0147H
Baud rate selection
72
0148H
Parity selection
73
0149H
Send waiting time
74
014AH
RTS control
75
76
77
78
014EH
Fault history
79
014FH
Software No.
1. Upper limit of setting range and initial setting are doubled at 400 class.
2. Changes depending on inverter capacity. Refer to the next page.
3. Initial setting of the model with digital operator (without volume) is 1.
Setting can be set to 0 by parameter initialization.
32
All manuals and user guides at all-guides.com
Setting unit: 1
Setting range: 0 ~ 32
0: 2400 bps
1: 4800 bps
2: 9600 bps
3: 19200 bps
0: Even parity
1: Odd parity
2: No parity
Setting unit: 1 = 1ms
Setting range: 10 ~ 65 ms
0: RTS control enabled.
1: RTS control disabled.
0: Execution completed / execution
command receive condition
1: READ execute
2: COPY execute
3: VRFY execute
4: kVA display
5: Software No. display
0: READ prohibited.
1: READ allowed.
The 1 newest event is displayed
(Note) Setting is disabled.
Lower 3 digits of software numbers are
displayed.
(Note): Setting is disabled.
Initial
Setting
0
2
0
10ms
0
-
-
User
Ref.
Setting
Page
-
-
-
-
-
54
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents