Carrier Frequency Varies According to Inverter Capacity (kVA).
Capacity
Voltage Class
hp(kW)
0.13 (0.1)
0.25 (0.2)
0.5 (0.4)
200V
Single-phase
1 (0.75)
3-phase
2 (1.5)
3 (2.2)
5 (3.7)
0.25 (0.2)
0.5 (0.4)
1 (0.75)
400V
2 (1.5)
3-phase
3 (2.2)
4 (3.0)
5 (3.7)
(1) Reduce continuous output current by changing carrier frequency to a
setting of 4 (10 kHz) for 200V class inverters (size > 1.5kW) and all 400V
class inverters. Refer to the table above for the reduced current.
[Operation Condition]
• Input power supply voltage: 3-phase 200 to 230V (200V class)
• Ambient temperature:
(2) If the wiring distance is long (approx. 50 meters), reduce the inverter car-
rier frequency as described below.
Wiring Distance between
Inverter and Motor
Carrier frequency
(n46 setting)
(3) Carrier frequency can be automatically reduced to 2.5 kHz when (n75) is set
to 1 and the following conditions are satisfied.
Output frequency < 5Hz
Output frequency > 100%
Factory Setting (n75) is 0 (disabled)
80
All manuals and user guides at all-guides.com
Initial Setting
Carrier
Setting
Frequency
4
10kHz
4
10kHz
4
10kHz
4
10kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
3
7.5kHz
Single-phase 200 to 240V (200V class)
3-phase 380 to 460V (400V class)
14 to 122
Up to 50m
10kHz or less
(n46=1, 2, 3, 4,
7, 8, 9)
Maximum
Reduced
Continuous
Current (A)
Output Current
*1
(A)
0.8
1.6
3.0
5.0
8.0
7.0
11.0
10.0
17.5
16.5
1.2
1.0
1.8
1.6
3.4
3.0
4.8
4.0
5.5
4.8
7.2
6.3
9.2
7.6
o
o
F (-10 to +50
C)
Up to 100m
More than 100m
5kHz or less
2.5kHz or less
(n46=1, 2,
(n46=1, 7, 8, 9)
7, 8, 9)