YASKAWA VS MINI J7 Series Instruction Manual page 28

Compact general-purpose inverter (voltage vector control)
Hide thumbs Also See for VS MINI J7 Series:
Table of Contents

Advertisement

Register
No. for
No.
Name
Trans-
mission
Parameter selection at
34
0122H
electronic thermal motor
protection
Cooling fan operation
35
0123H
selection
Multi-function input
36
0124H
selection 2
Multi-function input
37
0125H
selection 3
Multi-function input
38
0126H
selection 4
Multi-function input
39
0127H
selection 5
28
All manuals and user guides at all-guides.com
Description
Setting unit: 1min
Setting range: 1 ~ 60min
0: Controls the cooling fan OFF / ON
1: Operates when power is ON.
1: Not used
2: Reverse run reference (2 wire
sequence)
3: External fault (N. O. contact input)
4: External fault (N. C. contact input)
5: Fault reset
6: Multi speed reference 1
8: Multi speed reference 2
7: Multi speed reference 3
9: Not used
10: Jog reference
11: Accel / decel time switching refer-
ence
12: External baseblock reference
(N. O. contact input)
13: External baseblock reference
(N. C. contact input)
14: Speed search command from Max.
output frequency
15: Speed search command set fre-
quency
16: Accel / decel hold
17: Local / remote switching
18: Communication / control circuit ter-
minal switching
19: Emergency stop fault
(N. O. contact input)
20: Emergency stop alarm
(N. O. contact input)
21: Emergency stop fault
(N. C. contact input)
22: Emergency stop alarm
(N. C. contact input)
23~ 33: Unused
0: Forward / reverse command
(3 wire sequence)
Others are the same as parameter 36
Same as parameter 36
Same as parameter 36
34: Up/down reference
35: Self-test
(Note: valid power ON / OFF)
Initial
*User
Ref.
Setting
Setting
Page
8 min
94
0
96
2
82
5
84
3
84
6
84