backs each 3400JF model Fountain with a 2 Year War-
ranty. This warranty covers any and all manufacturers
defects within 2 years from the date of purchase (See
Warranty & Return Policy).

USE AND OPERATION

Kasco Fountains are designed and engineered for
continuous duty, such as on fish farms or other aqua-
culture applications, or on-demand use, as needed in a
recreational water feature.
During flotation operation, the water is pulled from
360
around the unit and from below the unit. The
O
water is pulled upward and thrust through the flotation
collar into the air.
Your Kasco Marine Fountain is ready for immediate
use (after installation). The motor and ball bearings
are submerged in oil and no further lubrication is
needed. Make sure to keep the motor housing clean
from hard water deposits and/or algae. (See Mainte-
nance Recommendations.)
It is extremely important that proper and sufficient
voltage (120V or 240/208V) is supplied to the Foun-
tain motor. Each 120V Fountain is supplied with a
UL and CSA approved C-25 GFI Protected Control
Box. The Fountain is to be plugged into the C-25
outlet labeled "UNIT" and the C-25 plugged into a
properly grounded receptacle (See C-25 Instructions
on page 12). Each 240V Fountain is supplied with a
UL and CSA approved C-85 GFCB Protected Control
Panel. The Fountain is to be plugged into the external
outlet on the C-85 or hardwired into C-85 panel. The
C-85 must have 4 wire service (L1, L2, neutral, and
ground) installed by a qualified electrician. (See Wir-
ing Instructions). It is extremely important to test the
GFI breaker in the control panel upon each installation
and reinstallation and every month thereafter to ensure
proper operation.
Kasco Fountains are lightweight, energy efficient, and
easy to install and operate. We strive to produce prod-
ucts that exceed customer expectations. We hope you
enjoy your Kasco Fountain.

UNIT STORAGE

When storing units during the offseason, it is impor-
tant to store them upside down if they are going to be
sitting for long periods of time. Units that sit upright
on a shelf for many months, or even years have a
greater likelihood of seals drying out. Storing upside
down will ensure oil is lubricating the seals and pre-
vent drying.

Cord Gauge Chart

Length Gauge 3400 3400H
50'
16
50'
14
100'
14
100'
12
150'
12
150'
10
200'
12
200'
10
250'
12
300'
12
400'
12

Unit Specs

Model
Voltage
Amps
3400JF
110-120
3400HJF
208-240
4400JF
110-120
4400HJF
208-240
4400
4400H
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Lock
Control
rotor
box con-
amps
nection
7.3
18
C-25
plug in
3.7
9
Hardwire
C-85
11
40
C-25
plug in
5.5
20
Hardwire
C-85
Fountain
connec-
tion
Plug into
C-25
plug into
or hard-
wire C85
Plug into
C-25
plug into
or hard-
wire C85
3