Areas of Application

The dirty water submersible pump is a
drainage pump and designed for trans-
porting water and sewage water (max.
particle size 35 mm) up to a temperature
of max. 35 °C.
It is suitable e.g. for pumping around and
pumping out basins and containers, for
pumping out flooded cellars, and for ex-
tracting water from wells and shafts.
This equipment is not suitable for industrial
use. Industrial use will invalidate the guar-
antee.
Any other use, not expressly authorised in
these instructions, may cause damage to
the equipment and represent a serious risk
for the user.
The pump is not suitable for continuous
operation. Continuous operation reduces
the durability and shortens the guarantee
period.
The operator or user is responsible for ac-
cidents or damage to other people or their
property.
The manufacturer shall not be liable for
damages caused by use other than for
which the equipment is intended or by in-
correct operation.

General Description

The diagram of the most impor-
tant functional elements can be
found on the foldout side.

Scope of Delivery

Carefully unpack the appliance and check
that it is complete. Dispose of the packag-
ing material correctly.
-
Fully assembled dirty water
submersible pump
-
Angle adapter
-
Reducer
-
8 m nylon cord
-
Instruction Manual

Functional description

The dirty water submersible pump has a
stainless steel casing, a stable suction foot
and a non-corrosive motor shaft. The pump
is fitted with a float switch, which automati-
cally switches the equipment on or off.
The motor is protected from overload by a
thermal safety switch.
Please refer to the following descriptions
for the function of the operating parts.

Overview

1 Round handle
2 Pump housing
3 Pump outlet
4 Floor plate
5 Foot part
6 Mains connection cable
7 Float switch
8 Float switch grating
9 Reducer
10 Angle adapter
11 8 m nylon cord
GB