No Function - Fronius ActiveCharger 1000 Operating Instructions Manual

Rod electrode power source for fronius accupocket 150/400
Table of Contents

Advertisement

E18
Cause:
Remedy:
E19 / E22
Cause:
Remedy:
E23
Cause:
Remedy:

No function

The power source cannot be switched on
Cause:
Remedy:
Cause:
Remedy:
Battery is not charged
Power source is connected to the charger, charger is connected to the mains, no charging
indicator on the power source
Cause:
Remedy:
Cause:
Remedy:
No welding current
Power source is switched on, indicator for the selected welding process is lit
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
52
Wrong firmware (software) has been loaded
Contact after-sales service
Battery fault
Contact after-sales service
A voltage of > 113 V DC has been measured on the current sockets
Contact After-Sales Service
The battery has entered a state of deep discharge as it has been stored for
too long without being charged
Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Control panel defective
Contact After-Sales Service
Device is too hot
Check/reduce ambient temperature, allow battery to cool down
Device temperature too low
Check/increase ambient temperature
Welding power-lead connections have been disconnected
Establish proper welding power-lead connections
Poor or no earth
Establish a connection to the workpiece
There is a break in the power cable in the welding torch or electrode holder
Replace welding torch or electrode holder