E65 - E75
Cause:
Remedy:

No function

The device cannot be switched on
Cause:
Remedy:
No welding current
Power source is switched on, indicator for the selected welding process is lit
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
No welding current
Device switched on, indicator for the selected welding process is lit, overtemperature indi-
cator lit
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
46
Communication error with welding torch/remote control
Check TIG Multi Connector plug connection / switch device off and on again
/ contact after-sales service if a repeated occurrence
Mains switch is faulty
Contact After-Sales Service
Welding power-lead connections have been disconnected
Establish proper welding power-lead connections
Poor or no earth
Establish a connection to the workpiece
There is a break in the power cable in the welding torch or electrode holder
Replace welding torch or electrode holder
Duty cycle exceeded - device overloaded - fan running
Keep within duty cycle
Thermostatic automatic circuit breaker has switched off the device
Wait until the power source comes back on automatically at the end of the
cooling phase (do not switch off the device - the fan will cool it down)
The fan in the power source is faulty
Contact After-Sales Service
Insufficient cooling air intake
Ensure adequate air supply
Air filter is dirty
Clean air filter
Power module error
Turn off the device, then turn it on again
If the error occurs frequently, contact After-Sales Service