Service Messages - Fronius ActiveCharger 1000 Operating Instructions Manual

Rod electrode power source for fronius accupocket 150/400
Table of Contents

Advertisement

Deep discharge protection
"Lo" appears in the display, the "Battery capacity" indicator flashes
Cause:
Remedy:
Deep discharge can destroy the battery.
Do not store the battery when it is in this state
Service messag-
When E and a 2 digit error number appear in the display (e.g. E02) and the "Error" indicator
es
lights up, this is an internal power source service code.
Example:
Make a note of the error numbers shown in the display, and of the serial number and con-
figuration of the power source, and contact our after-sales service team with a detailed de-
scription of the error.
E02 / E03 / E05 / E06
Cause:
Remedy:
E07
Cause:
Remedy:
E09 / E10
Cause:
Remedy:
E11
Cause:
Remedy:
E12 / E13 /E14
Cause:
Remedy:
E16
Cause:
Remedy:
+
Battery discharged, deep discharge protection has been activated
Charge the battery now
Battery operation is possible again above 25% capacity
CAUTION!
It is also possible that several error numbers are present. These appear when turning
the adjusting dial.
Internal temperature sensor fault on ACCUPLT / ACCUPLT-TIG PC board
Contact after-sales service
15 V supply voltage too low
Contact after-sales service
Load too high on power source current sockets
Use power source correctly (welding)
No communication with the control panel
Contact after-sales service
Internal error on ACCUPLT / ACCUPLT-TIG PC board
Contact after-sales service
Communication error between battery and ACCUPLT / ACCUPLT-TIG PC
board
Contact after-sales service
51