Battery protection functions

General

The battery protection functions serve to:
-
-
-
Deep discharge
The power source has a deep discharge protector to warn the user if the state of charge of
protector
the battery is too low. If this is the case, the power source switches off.
Function of the deep discharge protector:
-
-
Storing the battery for longer periods in a discharged state may damage the battery.
If the deep discharge protector is triggered, charge the power source immediately.
Automatic
Automatic switch-off avoids unnecessary power consumption, thereby extending the effec-
switch-off
tive period of operation with one battery charge.
If the power source is not operated for a specific length of time, it switches off automatically.
To reactivate the power source, press the On/Off button for at least two seconds.
NOTE!
The factory setting for the automatic switch-off time is 15 minutes (if no welding is
performed for 15 minutes, the power source switches off automatically).
This value can be changed in the Setup menu using the tSd parameter.
increase the service life of the battery
protect the battery from long-term damage
increase the reliability of the power source
when the battery capacity is exhausted
-
all segments of the battery capacity indicator flash
-
"Lo" is shown on the display
-
welding is no longer possible
the power source switches off automatically after three minutes
CAUTION!
29