Pin assignment
For diagnostic purposes, the RJ45 sockets are each equipped with a green and an orange LED.
This allows the following status information about the respective PROFINET port to be
displayed:
Table 8-6
Signal type: O = Output; I = Input
Table 8-7
B = Bidirectional
Note
The PROFINET interface has what is known as autocrossing functionality, i.e. when required,
transmit and receive lines are switched over. Thus, no crossover cables are necessary.
MCU 1720
Equipment Manual, 09/2019, A5E47437728B AB
Assignment of PROFINET interfaces X150, ports 1, 2 in the 10/100 MBit/s mode
Connector
Pin
1
2
3
4/5
6
7/8
Shield
-
-
Assignment of PROFINET interface X160 in the 10/100 MBit/s mode
Connector
Pin
1
2
3
4
5
6
7
8
Shield
-
-
Name
Type
TxD+
O
TxD-
RxD+
I
GND
-
RD-
I
GND
-
-
-
LED green
-
(Link)
LED orange
-
(Activity)
Name
Type
DA+
B
DA-
DB+
DC+
DC-
DB-
DD+
DD-
-
-
LED green
-
(Link)
LED orange
-
(Activity)
8.10 PROFINET
Remark
Transmit data
Receive data
(terminated internally with 75 Ω; not re‐
quired for data transmission)
Receive data
(terminated internally with 75 Ω; not re‐
quired for data transmission)
On connector housing
Lit: 10 or 100 Mbit/s
Off: No or faulty connection
Flashes: Data exchange
Off: No data exchange
Remark
Bidirectional pair A+
Bidirectional pair A-
Bidirectional pair B+
Bidirectional pair C+
Bidirectional pair C-
Bidirectional pair B-
Bidirectional pair D+
Bidirectional pair D-
On connector housing
Lights up orange: 1000 Mbit/s
Off: No or faulty connection
Flashes: Data exchange
Off: No data exchange