Christie RPMX-D120U Setup Manual page 48

Table of Contents

Advertisement

Section 4: Maintenance
4-8
6. Tighten the three lamp screws on the new lamp module to "lock" it in place.
Then, lower the lamp handle until it clips in place.
Lamp handle must lay flat before requesting a lamp
7. If the other lamp requires replacement, change the lamp position to gain
access to the other lamp. Allow the lamp to cool and proceed with lamp
replacement following the same steps described earlier.
8. Each new lamp is supplied with a lamp card that contains lamp specific
information such as the serial number. This card must be replaced whenever
a lamp is replaced. Remove the corresponding lamp card from the PHM
module and replace it with the new lamp card. The projector will detect the
new card when the projector is powered up and read the new lamp serial
number.
Figure 4.5. Insert New Lamp
WARNING
position change.
Figure 4.6. Replace Lamp Card\
RPMX-RPMSP-D120U & RPMSP-D275U Setup Guide
020-100038-02 Rev. 1 (09/08)