Christie RPMX-D120U Setup Manual page 39

Table of Contents

Advertisement

Error Codes
RPMX-RPMSP-D120U & RPMSP-D275U Setup Guide
020-100038-02 Rev. 1 (09/08)
numerical error code which is shown in the status display window. A system
malfunction can be cleared with
indicate the need for service by a qualified service technician.
NOTE: System messages appear on-screen only if Display Error Messages has
been set to "Screen" or "All".
System Warnings
A system warning indicates that a system malfunction has been detected. A
system warning message replaces any input signal message and disappears when
the input signal status changes. While the projector will remain operational, the
message indicates the presence of a potentially serious problem that should be
reported to the manufacturer. You can press
for best results you should reset the projector—power the projector down and up
again with the
(power) key.
System Errors
A system error message indicates that a serious malfunction has been detected
and must be reported to the manufacturer as soon as possible. The projector will
no longer operate and must be reset—power the projector down and up again
with the
(power) key.
The Status Display
If one of the error codes in table is shown in the status display window then you
have likely encountered a system error that will require the attention of a
qualified service technician. Acknowledge and clear the error with
from presentation level, or try resetting the projector by powering it off and on
again, cooling when necessary. Consult and contact your dealer if the problem
persists.
Code
Description
GENERAL
12
Software bug. Contact dealer/factory.
13
Flash memory corrupted. Download new software.
14
Engineering-only programming is complete. Call Christie, replace TIPM.
15
Attempting to download code without being in boot mode
16
Invalid interrupt. Power off/on. If it persists, contact dealer/factory.
18
Attempting to program boot mode without jumper
8D
Engine internal failure (all other failures)
TBD
Main processor programming failure
TBD
Motor processor programming failure
LAMP FAILURES
27
Lamp 1 Failed to Strike
28
Lamp 1 Turned Off Unexpectedly
32
Lamp 2 Failed to Strike
33
Lamp 2 Turned Off Unexpectedly
38
Lamp Position Failure
39
Lamp 1 Card Not Installed
3A
Lamp 2 Card Not Installed
POWER AND COOLING
53
Lamp Fan Failure
54
DMD Fan failure
55
Ballast A Fan Failure
56
Ballast B Fan Failure
57
Color Wheel Fan Failure
TIPM (image processor)
60
Boot code CRC failed
61
Unable to program the DigMux PLD
62
Unable to program the Control PLD
63
Unable to program the BUBKS PLD