RPMX-RPMSP-D120U & RPMSP-D275U Setup Guide
020-100038-02 Rev. 1 (09/08)
3. Using a screwdriver, completely loosen the three lock screws on the lamp
module held in the reserve position.
Figure 4. 3. Remove Lamp Lock Screws
4. Using the lamp handle, pull the lamp straight up to remove from the projector.
5. Discard the lamp using approved disposal methods for your area. NOTE: Lamps
containing mercury must be treated as hazardous waste if discarded in large
volumes.
Do not stick your hands in an empty lamp compartment.
5. Handling the new lamp by its handle only, align it with the terminal plug located
on the side wall of the lamp compartment. Insert the lamp all the way in until it
is fully seated – the lamp connector will plug into the terminal plug.
Figure 4.4. Remove Lamp
WARNING
Section 4: Maintenance