Changing The Settings - DeDietrich MODULENS O AFC 18 Installation And Service Manual

Oil-fired condensing boilers
Hide thumbs Also See for MODULENS O AFC 18:
Table of Contents

Advertisement

AFC 18 - AFC 24 - AFC 30
User level - #MEASURES Menu
Parameter
Description
Injection nozzle oil pressure
OIL PRESSURE
Water temperature in the DHW tank
(1)
WATER TEMP.
(1)
Instant hot water temperature
TEMP DHW INST
Water temperature in the storage tank
STOR.TANK.TEMP
(1)
(1)
Water temperature of the swimming pool on circuit B
SWIMMING P.T.B
Water temperature of the swimming pool on circuit C
(1)
SWIMMING P.T.C
(1)
Temperature of the flow water in circuit B
OUTLET TEMP.B
Temperature of the flow water in circuit C
(1)
OUTLET TEMP.C
(1)
Temperature of the system flow water if multi-generator
TEMP.SYSTEM
Water temperature in the bottom of the DHW tank
(1)
T.DHW BOTTOM
Water temperature in the second DHW tank connected to the AUX circuit
(1)
TEMP.TANK AUX
(1)
Water temperature in the second DHW tank connected to circuit A
DHW A TEMP.
Temperature of the hot water produced by solar power (TS)
(1)
TEMP.SOL.TANK
(1)
Solar panel temperature (TC)
SOLAR.COLL.T.
Solar energy accumulated in the tank
(1)
SOLA.ENERGY
Temperature of the boiler return water
BACK TEMP
Instantaneous boiler output (0%: Burner off or running at minimum output)
POWER
Energy consumed by the boiler in heating mode
(2)
HEATCONS.
(2)
Energy consumed by the boiler in DHW mode
DHW CONS.
Instant boiler output
POWER KW
Number of burner starts (not restartable)
NB IMPULS.
The meter is incremented by 8 every 8 start-ups
Number of burner operation hours (not restartable)
RUNTIME
The meter is incremented by 8 every 8 hours
(1)
Voltage at input 0-10 V
IN 0-10V
Control system sequence
SEQUENCE
Software control number
CTRL
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the #CONFIGURATION} menu)
6.7

Changing the settings

09/07/2015 - 300026439-07
The boiler control panel is set for the most common heating
systems. With these settings, practically all heating systems operate
correctly. The user or installer can optimise the parameters according
to own preferences.
¼For the user settings, refer to the user instructions.
6. Commissioning
Unit
bar (MPa)
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
kWh
°C
%
kWh
kWh
kW
h
V
111