NO.
POTENTIAL
REASONS
1
LCD no display.
2
No alteration of
resistance
3
No hand pulse
figure display
4
No
display
of
Built-in figure
5
LCD display E-1
6
LCD display E-4
7
LCD display E-2
8
LCD display E-3
9
No
display
of
SPEED figure
10 Fail to respond
the RECOVERY
function.

TROUBLESHOOTING

1. Check the meter together with the stage's 9 or 12 PIN connect cable, to see if
the meter has bad contact or get loose with the stage's 9 or 12 PIN connect
cable.
2. Check if the DC JACK 3PIN connect cable are loose or not.
1. When the LOAD/LEVEL is up or down, see if the motor is running or not.
2. Check the meter together with the stage's 9 or 12 PIN connect cable, to see if
the meter has bad contact with or has loosened from the stage's 9 or 12 PIN
connect cable.
3. See if the motor is running or not after plug in the adaptor again and turn on the
meter.
1. Make sure the user holds onto the handgrip sensor. Please hold two hands
together during training period.
2. Check the signal cable which in the pulse sensor to see if it is loose or not.
3. To see the meter whether in the low-speed (energy saving mode) or not.
1. Check the battery is dead or not, please change the battery and test it again.
2. See the meter whether in the low-speed (energy saving mode) or not.
1. E-1 indicates the meter does not receive the body fat figure. Make sure the user
holds onto the handgrip sensor. Please do hold two hands together during
training period.
1. E-4 is indicate the user's age, height, weight figure exceeds the setting range when
user setting their information.
1. Check the meter together with the stage's 9 or 12 PIN connect cable, to see if
the meter has bad contact with or has loosened from the stage's 9 or 12 PIN
connect cable.
2. Check if the motor distance exceeds the setting range or not.
1. Check whether the motor 2 PIN cable is connected or not.
2. Check whether the switch cabinet is fixed too far away.
3. Check if motor cable is broken or connected well to meter.
4. Change the switch cabinet.
5. Change another meter to test. If it displays correctly, then it is meter problem. If
it still displays E-3, contact customer service.
1. Check the meter together with the stage's 9 or 12 PIN connect cable, to see if
the meter has bad contact with or has loosened from the stage's 9 or 12 PIN
connect cable.
2. Check the speed sensor cable, to see if it is bad contact or getting loose.
1. Check if the meter is in the STOP condition or not.
2. Check the pulse function to see if it can display the pulse figure or not.