Leave a small break of at least 15 seconds between two
measurements.
If you are pregnant, you should monitor your blood pressure
very closely as it can change drastically during this time!
If you suffer from an irregular heartbeat (arrhythmia, see
«Section 4.»), measurements taken with this instrument should
only be evaluated after consultation with your doctor.
The pulse display is not suitable for checking the
frequency of heart pacemakers!

How do I evaluate my blood pressure?

Table for classifying blood pressure values in adults in accordance
with the World Health Organisation (WHO) in 2003. Data in mmHg.
Range
Systolic Diastolic Recommendation
blood pressure
100
too low
1. blood pressure
100 - 120 60 - 80
optimum
2. blood pressure
120 - 130 80 - 85
normal
3. blood pressure
130 - 140 85 - 90
slightly high
4. blood pressure
140 - 160 90 - 100
too high
5. blood pressure
160 - 180 100 - 110
far too high
6. blood pressure
180
dangerously
high
The higher value is the one that determines the evaluation.
Example: a readout value between 150/85 or 120/98 mmHg indi-
cates «blood pressure too high».
The slot-in card 3 on the front of the instrument shows ranges
1-6 in the Table.
14
60
Consult your doctor
Self-check
Self-check
Consult your doctor
Seek medical advice
Seek medical advice
110
Urgently seek
medical advice!

2. Using the Instrument for the First Time

Activate the fitted batteries

Pull out the protective strip projecting from the battery compart-
ment 7.

Setting the date and time

Your aponorm® Professional upper arm blood pressure monitor is
equipped with a radio clock, which is controlled by the DCF77
signal. This time and date are set automatically. If no DCF77 sig-
nal (this is the term for the time signal transmitter) is available,
the time is not adjusted automatically.
The display comes to receiving mode and device sets the time
automatically, if you drag the zip to activate the batteries (or
insert batteries).
If you do not wish to set the time or you want to take a
measurement immediately, exit the time setting mode by
pressing the On/Off button.
Once the time signal is received, the radio clock icon
on the display every second until the reception of the DCF77
signal is complete.
While receiving the DCF77 signal, the radio clock icon
fi rst with 1, then 2 and then 3 bars above it. When the icon appears
with 3 bars, the time has been set. First the date and then the
time are displayed at the top right of the display. Then the time is
displayed permanently together with the radio clock icon
The automatic setting of date and time takes about 2-4
minutes. If no signal is received within 10 minutes, „-: - -"
appears on the display.
Now you need to improve the reception by choosing another
location or set the clock manually (for more information see
„manual setting"). After a change of location, batteries have to
be re-inserted or to reset radio clock to „ON" to restart the auto
setting again.
Manual setting (if automatic setting does not work or is not desired):