Analog And Digital Signal Processing Chain - Dalsa Piranha HS Series User Manual

High sensitivity line scan ccd camera
Hide thumbs Also See for Piranha HS Series:
Table of Contents

Advertisement

52
Notes:
Related Command s
Example:

4.5.2 Analog and Digital Signal Processing Chain

Processing Chain Overview and Description
The follow ing d iagram show s a sim plified block d iagram of the cam era's analog and
d igital processing chain. The analog processing chain begins w ith an analog gain
ad ju stm ent, follow ed by an analog offset ad ju stm ent. These ad ju stm ents are applied to
the vid eo analog signal prior to its d igitization by an A/ D converter.
The d igital processing chain contains the FPN correction, the PRN U correction, the
backgrou nd su btract, and the d igital gain and offset. All of these elem ents are u ser
program m able.
Notes:
03-032-20013-03
All manuals and user guides at all-guides.com
column start number in a range from 2 to column resolution.
y2
Row end num ber. Must be greater than or equal to the row
start number in a range from 2 to number of stages except in
TDI Mod e w here y2 must be 1.
If you are using binning, the start pixel is round ed d ow n to
the beginning of binned area and end pixel is round ed up to
the end of the binned area.
In Area Mod e, the roi must be w ithin the stage. If the
requested roi is above the stage, the roi row s w ill be clipped .
The start and end row s w ill be clipped to the stage selection
if necessary. A ―clipped to max‖ w arning message is
returned .
ccg, cao, cpa, gl, gla, ccf, ccp,
roi 10 1 50 1 (TDI Mod e)
FPN and PRN U correction is not available w hen operating the cam era in Area Mod e.
For d etails on how to sw itch cam era operation m od es, refer to section 4.5.1 .
The follow ing u ser settings are stored separately for forw ard and reverse d irection;
analog gain, analog offset, d igital gain, d igital offset, and backgrou nd su btract. They
wus
are saved u sing the
com m and .
FPN and PRN U coefficients are stored separately for forw ard and reverse d irection.
To save the cu rrent PRN U coefficients, u se the com m and
FPN coefficients, u se the com m and
only.
Piranha HS-xx RoHS User Manual
els
wpc
. To save the cu rrent
wfc
. Settings are saved for the cu rrent d irection
Teledyne DALSA

Hide quick links:

Advertisement

Table of Contents
loading