Extron electronics CrossPoint 450 Plus 84 HV User Manual page 91

Table of Contents

Advertisement

im Vertrieb von
www.camboard.de
CAMBOARD Electronics
Perform a soft reset of the switcher as follows:
1.
Press and hold the Reset button until the front panel RGBHV
(CrossPoint 450 Plus)/Video (MAV Plus) and Audio buttons blink once
(events reset), twice (system reset), or three times (absolute reset) (figure 3-80).
Press and hold
the Reset button.
Events Reset
Press and hold
the Reset button.
IP Settings
Reset
Press and hold
the Reset button.
Absolute Reset
NOTE
The Reset button on switchers with matrix sizes of 24 x 12 and above
have a different appearance and do not have a rear panel Reset LED.
Figure 3-80 — Whole switcher and absolute resets
2.
Release the Reset button and then immediately press and release the Reset
button again. Nothing happens if the second momentary press does not
occur within 1 second.
Tel. 07131 911201
CrossPoint 450 Plus and MAV Plus Switchers • Operation
Fax 07131 911203
press and release again.
I / O
3 seconds
RGBHV AUDIO
Buttons and Reset LED flash once.
1
press and release again.
I / O
6 seconds
VIDEO
AUDIO
Buttons and Reset LED flash twice.
2
press and release again.
I / O
9 seconds
RGBHV AUDIO
Buttons and Reset LED flash three times.
3
ce-info@camboard.de
Release, then
immediately
Release, then
immediately
Release, then
immediately
3-51

Advertisement

Table of Contents