Honeywell AlarmNet GSMHS Installation And Setup Manual page 29

High security gsm cellular communicator
Table of Contents

Advertisement

PROMPTS
38
Delay Zn3 (secs)
(00)
Rpt Zn3 ONLY if
39
Armed (N)_
40
Zn4 Trigger Type
(V+)_
41
Invert Zn4 Y/N
(N)_
42
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
43
(00)
Rpt Zn4 ONLY if
44
Armed (N)_
Zn5 Trigger Type
45
(V+)_
46
Invert Zn5 Y/N
(N)_
Restore Zn5 Y/N
47
(Y)_
48
Delay Zn5 (secs)
(00)_
Rpt Zn5 ONLY if
49
Armed (N)_
Enable Zn6 Y/N
50
(N)_
Zn6 Trigger Type
51
(V+)_
Invert Zn6 Y/N
52
(N)_
4204/
ZONE
ENTRY
2-4204
TRIG.
2-
4204
only
2-
4204
only
2-
4204
only
2-
4204
only
4204
only
4204
only
4204
only
Section 3: Programming the GSMHS
OPTIONS
[01-15]
Defines the reporting delay in seconds for
zone 3.
[00] = no
UL: Must be set to "00."
delay
Reports alarms on zone 3 ONLY if the
[Y], [N]
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to
"Report Only if Armed," skip to Prompt 50:
"Enable Zn6."
 (EOLR)
Selects the triggering method for this zone
 (V+)
input.
 (V–)
Press the [space] key to scroll through choices.
[Y], [N]
Inverts the alarm and normal states of the
zone 4 trigger; otherwise uses normal input
signal.
[Y], [N]
Enables restore reporting for zone 4.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 4.
[00] = no
UL: Must be set to "00."
delay
[Y], [N]
Reports alarms on zone 4 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
 (EOLR)
Selects the triggering method for this zone
 (V+)
input.
 (V–)
Press the [space] key to scroll through choices.
[Y], [N]
Inverts the alarm and normal states of the
zone 5 trigger; otherwise uses normal input
signal.
[Y], [N]
Enables restore reporting for zone 5.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 5.
[00] = no
delay
UL: Must be set to "00."
[Y], [N]
Reports alarms on zone 5 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
[Y], [N]
Enables alarm reporting for zone 6.
If [N], skip to Prompt 56: "Enable Zn7."
 (EOLR)
Selects the triggering method for this zone
input.
 (V+)
Press the [space] key to scroll through choices.
 (V–)
[Y], [N]
Inverts the alarm and normal states of the
zone 6 trigger; otherwise uses normal input
signal.
DESCRIPTION
3-15

Advertisement

Table of Contents
loading

Table of Contents