Honeywell AlarmNet GSMHS Installation And Setup Manual page 18

High security gsm cellular communicator
Table of Contents

Advertisement

GSMHS Installation and Setup Guide
PROMPTS
Program Device?
3
(Y/N)_
Create Password?
4
(Y/N)_
Change Password?
5
(Y/N)_
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
(Y/N)_
9
Device Mode
(ECP)_
Important Information Regarding Primary and Secondary Accounts (Questions 10-16)
Account information is provided by the central station administrator. If the control supports secondary account
reporting, you will need secondary account information. The City ID, CS ID or Subscriber ID of the secondary
account must differ from that of the primary account.
Primary City ID
10
(??)_
11
Primary CS ID
(???)
Primary Sub ID
12
(????)
3-4
ENTRY
OPTIONS
[Y], [N]
[Y], [N]
[Y], [N]
[0-9, A-F, N,
S, T, X, Y]
[0-9, A-F, N,
S, T, X, Y]
[Y], [N]
[ESC]
 ECP
 Zone Trig.
 4204 Emu
 Two 4204s
[01-99]
[01-FE]
[0001-9999]
DESCRIPTION
To begin programming the module, press [Y] and go to
Prompt 9: "Device Mode."
To create a password if none has been assigned, press
[N] and go to Prompt 4: "Create Password."
To change an existing password, press [N] and go to
Prompt 5: "Change Password."
Passwords can be used to protect account and
programming information.
If no password has been assigned, this prompt appears
after pressing [N] at the "Program Device?" prompt.
If a password is desired, press [Y] and go to Prompt 6:
"Enter Password."
If a password has already been assigned, this prompt
appears after pressing [N] at the "Program Device?"
prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without
entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key when
prompted for the new password and its confirmation.
This prompt is displayed if [Y] was pressed in Prompt 4
or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in
this section.
Press the [space] key to scroll through the modes of
operation.
Press [ENTER] to select ECP mode.
See Table 2-4 if programming other modes.
Enter the 2-digit primary city ID, 01-99 (decimal).
Enter the 2-digit primary central station ID number,
01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).