ECP Status Codes

When the GSMHS is configured for ECP mode, it sends status messages to the control panels
for battery, power, tamper, and network connectivity failures. Some of the control panels,
(e.g., VISTA-10P, VISTA-15P and VISTA-20P Series) display these on the keypad as
"LngRng Radio" followed by a 4-digit code (listed below). In addition, the Contact ID codes
(listed in Appendix B) for these conditions are sent to the central station by the module.
STATUS CODE
0000
0880
0005
000F
0019
0400
0C80
0C8F
08E0
3000
8000
0060

Alternative Mode Programming (Zone Trigger, 4204 and Two-4204)

Zone Trigger Mode

There are six input zones available on the GSMHS. Each zone is selectable for +V, -V, or
EOLR trigger. The first zone input can detect both pulsed and steady signals if connected to
a bell output.
When using Zone Trigger mode, messages are sent in ADEMCO High-Speed format.
Zones 3, 4, 5, 6 and 7 are voltage trigger inputs located on TB1 pins 6-10.
Refer to Table 2-4 for Zone Trigger Mode programming and follow the prompts that pertain
to Zone Trigger Mode.

4204 Emulation Mode

In 4204 Emulation Mode, the GSMHS communicates with a compatible Honeywell VISTA
series or First Alert control panel as though it were a 4204 Relay Module. If two 4204s are
enabled in the module, it acts as two 4204s at consecutive device addresses. The control
panel must be configured to recognize one or two 4204 relay modules accordingly. On
VISTA-32FB (or higher) control panels and First Alert equivalents, addresses 6 and 13
should not be used when the secondary 4204 is enabled. Messages are sent in ADEMCO
High-Speed format.
NOTE: See your control panel Installation and Setup Guide for the number of 4204 modules
3-8
Table 2-3. Common ECP Keypad Display Status Codes
Control panel lost communication with GSMHS.
GSMHS tamper detected (cover removed).
GSMHS has lost contact with AlarmNet-i network.
GSMHS is not registered; account not activated.
GSMHS shutdown.
GSMHS power on / reset AND the control panel lost communications with GSMHS.
GSMHS power on / reset AND tamper detected.
GSMHS power on / reset AND tamper detected AND not registered.
GSMHS tamper detected AND GSMHS battery low.
Primary power loss (will only be displayed in conjunction with another event).
Battery charger failure (will only be displayed in conjunction with another event).
Low battery (will only be displayed in conjunction with another event).
supported.