TRIGGERING DEVICE
Figure 2-3. Wiring the GSMHS Zone 1 Input for a Positive (+) Trigger
TRIGGERING DEVICE
Figure 2-4. Wiring the GSMHS Zone 1 Input for a Ground (-V) Trigger
Figure 2-5. Wiring the GSMHS Zone 1 Input for EOL Supervised N.O./N.C. Triggers
U L
2-4
GND
+ TRIGGER
(VOLTAGE: 6-12V)
GND
-
TRIGGER
(VOLTAGE: 0-1V)
NOTE: TRIGGER VOLTAGE
IS +V TO GROUND FALLING
EDGE TRIGGER
TRANSFORMER
N.C.
2K EOL
N.O.
RESISTOR
 Zones should use EOL resistors, and be programmed as V+ Inverted or V– Inverted operation
such that a cut line results in an alarm.
 Do not use zones 1 and 2 for UL installations.
TRANSFORMER
TB1
1
AC INPUT 1
AC INPUT 2
2
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATIONS
MODULE
TRANSFORMER
TB1
1
AC INPUT 1
AC INPUT 2
2
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATIONS
MODULE
TB1
1
AC
AC
2
GND
4
ZONE INPUT Z1/Z2
5
J1
COMMUNICATIONS
MODULE
BATTERY
J1
BATTERY
J1
BATTERY