Hilti DX 9-ENP Original Operating Instructions page 32

Hide thumbs Also See for DX 9-ENP:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
5.1.2
Checking that the tool is ready for use
This check should always be carried out immediately before use of the fastening tool and after
reassembling the tool after cleaning or after a routine check of the condition of the piston and piston
stopper.
1. Make sure that there are no cartridge strips and no nail strips in the tool.
2. Check the fastening tool for visible signs of damage,
especially to the components shown in the illustra-
tion.
Result
Visible signs of damage are found
▶ Have the tool repaired by Hilti Service.
3. Press the tool against the working surface until a definite resistance is felt and then check the position of
the pressure pin.
Result 1 / 2
The pressure pin is not pressed down – the spring on the pressure pin is not compressed.
The tool has detected no nail and thus cannot be pressed against the working surface. The tool is
working correctly.
Result 2 / 2
The pressure pin is pressed all the way down, the spring on the pressure pin is compressed and a click
is heard when the trigger is pressed.
The slider may be jammed. The tool should be cleaned again and the test repeated. If the problem
persists, the tool must be repaired by Hilti Service.
4. Release any pressure on the tool.
5. Load the nail strips → page 25, but do not load any cartridge strips.
6. Press the tool against the working surface again and check whether a click can be heard when the trigger
is pulled.
Result 1 / 3
The tool cannot be pressed fully against the working surface – triggering is not possible.
▶ Check that the rotating sleeve is closed. If necessary, turn the rotating sleeve to the left as far as it
will go.
▶ Check the position of the slider. If the slider has not clearly moved to the left, have the tool repaired
by Hilti Service.
Result 2 / 3
The tool can be pressed fully against the working surface (the spring on the pressure pin is fully
compressed) and a click is heard when the trigger is pressed.
The nail detector in the tool is working correctly and the tool can be used.
Result 3 / 3
The tool can be pressed fully against the working surface (the spring on the pressure pin is fully
compressed) but no click is heard when the trigger is pressed.
▶ Have the tool repaired by Hilti Service.
24
English
Catch
@
Pressure pin
;
Slider
=
Nosepiece
%
2241307