8.
Place the white connector of the perilex cord on connection X27.
9.
Feed the perilex cord through the cable recess. Place the strain relief in the
appropriate recess.
10. Screw the strain relief hand tight using a Torx screwdriver (key size T20)
11. Replace the top cover and re-tighten the 2 screws
12. Reinsert the earthed perilex cord into the cable clamp on the metal back frame
13. Place the plug in a perilex wall socket which is connected as shown in the
diagram below.
Speed control for perilex connection
A 230 Volt power supply (terminals L3 and N) must be
connected to the perilex wall socket. The speed is con-
trolled by means of a 3-position switch, which receives
power (L3) from the perilex socket (wire diameter 1.5
2
mm)
). A black (L2) and grey (L1) wire leads from the
switch back to the perilex wall socket. It is important
that terminal L3 is always supplied with voltage. For
the correct way to connect the cabling, see the wiring
diagram below. Optionally, an RF Remote Control, CO
Controlsensor or a CO
with the CV-3 switch. If several switches or controls are
used in the home, the last selected ventilation position
always takes precedence.
Explanation of 3 ventilation settings
Setting 1
Low
Setting 2
Medium
Position 3
High
Roomsensor can be combined
2
Absent setting
Present setting
High setting
2
For use during absence during a long
period
For daily use with normal use within
the home
For use during cooking, showering
or parties
index
13