Orcon HRC-EcoMax Series User Manual

Orcon HRC-EcoMax Series User Manual

Balanced ventilation system with heat recovery
Hide thumbs Also See for HRC-EcoMax Series:

Advertisement

User manual
HRC-EcoMax / HRC-MaxComfort
Balanced ventilation system with heat recovery
This manual is intended for end-users of the HRC-EcoMax and HRC-MaxComfort
balanced ventilation systems. This manual contains important information
about the operation and maintenance of the ventilation unit with heat
recovery, remote control, CO
room sensor and CO
control sensor.
2
2
The installer manual can be found on the right side of the unit.
This manual covers the following models:
HRC-300-EcoMax
HRC-300-MaxComfort
HRC-400-EcoMax
HRC-400-MaxComfort
HRC-500-EcoMax
HRC-500-MaxComfort

Advertisement

Table of Contents
loading

Summary of Contents for Orcon HRC-EcoMax Series

  • Page 1 User manual HRC-EcoMax / HRC-MaxComfort Balanced ventilation system with heat recovery This manual is intended for end-users of the HRC-EcoMax and HRC-MaxComfort balanced ventilation systems. This manual contains important information about the operation and maintenance of the ventilation unit with heat recovery, remote control, CO room sensor and CO control sensor.
  • Page 2 Index 1. Safety instructions 2. General operation of balanced ventilation system 3. Product information 4. Operating the unit 5. Maintenance 6. Malfunctions 7. Certification and warranty...
  • Page 3 Why ventilate? Orcon: exceptional indoor climate Our goal is to provide residents with an exceptional indoor climate that is as com- fortable and healthy as possible, in which they feel comfortable and can function optimally. With this aim in mind, we have grown to become a leading supplier of ventilation systems for residential homes and utilities.
  • Page 4: Precautions And Safety Instructions

    1. Precautions and safety instructions This document will assist you to operate and maintain the HRC safely and optimally. The HRC is referred to as "the unit" in this document. The unit is continuously under- going further development and improvement. This means that there is a possibility that the unit may deviate slightly from the descriptions.
  • Page 5 In order to create a healthy living environment in your home, good ventilation is required. Your home is therefore equipped with a mechanical supply and extractor ventilation system from Orcon bv. This system consists of a centrally arranged balance ventilation device (HRC-EcoMax/MaxComfort) with very energy-efficient DC motors,...
  • Page 6 Bypass In the summer, or when heat recovery is not desirable, the air is not passed through, but past the heat exchanger thanks to a bypass module. This makes it possible to ventilate the home with fresh outside air in the summer situation, during the night, so that the home is relatively cool again in the morning.
  • Page 7: Product Information

    3. Product information 3.1 Unit types The Orcon HRC is equipped with an intelligent electronic control circuit that ensures optimum operation and protection under all circumstances. The different models are listed in the table below. Each model is suitable for both left and right mounting.
  • Page 8: Operating The Unit

    4. Operating the unit 4.1 Operation with 3-position switch If your unit is equipped with a perilex connector and 3-position switch, the ventilation positions can be set from the table below. If several switches or controls are used in your home, the last selected ventilation position always takes precedence. Explanation of Ventilation settings For use during absence during a long Setting 1...
  • Page 9 Absent setting In the absent setting, the device runs in the minimum ventilation setting. Timer setting In the timer mode, the unit runs at the high setting for a required time; after the time has elapsed, the unit switches back to the last selected setting. The timer can be cancelled by selecting a different required setting.
  • Page 10 4.4 Control using the CO control sensor The HRC can also be operated with the CO Control sensor. This is CO sensor has an integrated control. By holding down the control button once, the status is displayed by the LEDs. After 30 seconds, the LEDs go out automatically, so as not to disturb a dark living space.
  • Page 11: Maintenance

    5. Maintenance The Orcon ventilation system components in the table below must be cleaned regularly. Clean Orcon ventilation system parts Action Interval Who? Clean filters 1x per 3 months User Replace filters 1x per 6 months User or installer Clean valves (and grilles)
  • Page 12 Remove the contaminated filters from the device using the pull tab. Vacuum clean the filters on the outside. If the filters are too dirty, they must be replaced. Order original Orcon filters to guarantee a good performance of the unit (www.orcon.nl/winkel).
  • Page 13 Maintenance of remote control Regularly remove the dust from the remote control with a dry cloth. If the LED indicator on the remote control flashes 1x orange or no longer responds to the operation, the battery is probably empty. You can easily replace it yourself. Battery position Wall frame Top part...
  • Page 14 User maintenance log Date/ Clean Clean Clean Fill condensation Action filters valves controls extractor...
  • Page 15 6. Malfunctions I. Remote control 15RF When a key on the remote control is pressed, the LED lights up green, then it will flash to confirm. The following indications are possible: Overview indications remote control RF15 Indication Remote control message Unit OK, message followed up 1x green Unit OK, timer activated for 15 minutes...
  • Page 16 III. Display The unit has a display fitted on the front. This LED can show a message depending on the colours of the LED and the number of times it lights up. An overview of potential indications is shown in the table under 7.2 IV. Printed circuit board. IV.
  • Page 17 20 different RF components to the unit. For the details, please refer to the instruction manual for the relevant RF component or www.orcon.nl. In operation After the learning mode, the unit will automatically switch to 'in operation mode'.
  • Page 18: Certification And Warranty

    State the type and serial number, which can be found on the type sticker under the unit. Orcon bv reserves the right to change the construction and/or configuration of its products at any time without the obligation to adjust previously delivered pro- ducts.
  • Page 20 Landjuweel 25, 3905 PE Veenendaal | Postbus 416, 3900 AK Veenendaal t +31 (0)318 54 47 00 | info@orcon.nl | www.orcon.nl...

Table of Contents