4.3 Changing the unit direction
The HRC is available in a left or right model. The HRC is by default supplied as a left
model. The ducts are therefore are connected to the home on the left side of the unit,
and the ducts on the right side of the unit go outside. If you wish to use the HRC as a
right model, it can be configured as follows:
1. Remove the plug from the socket
2. Place the device on a flat surface if the device is already suspended
3. Remove both filter covers
4. Remove the plastic front plate
5. Remove the metal front plate of the device by removing the 5 screws
(wrench size T25)
6. Take the power cord out of the cable clamp on the metal back plate
7. Remove the metal back plate of the device by removing the 5 screws.
8. Move the metal front plate to the other side of the device and fasten the 5 screws
9. Move the metal back plate to the back of the device and fasten the 5 screws
10. Remove the circuit board cover on the top. Keep an eye on the length of the display
cable when removing the circuit board cover. If necessary, temporarily separate it
from the connector on the circuit board
11. Move the earthing cable to the new back of the device. Move the strain relief
towards the recesses at the other wide of the circuit board as well
12. Reinstall the top cover such that the display is located at the front and fasten the 2
screws.
13. Return the earthing cable to the cable clamp on the metal back plate
14. Place the plastic front plate back to cover the metal front plate. Secure the front
plate by pressing on the four outer corners
15. Reinstall the filter covers.
The device is now suitable for installation in a right-handed setup.