Sungrow SG33CX User Manual page 58

Pv grid-connected inverter
Hide thumbs Also See for SG33CX:
Table of Contents

Advertisement

5 Electrical Connection
Pull the cable gently to make sure it is secured, tighten the swivel nut
Step 8
clockwise.
RJ45 network port
Remove the communication junction box, see 5.7.1 Remove the
Step 1
Junction Box.
Strip the insulation layer of the Ethernet cable with a wire stripper, and
Step 2
insert the signal wires to the RJ45 connector. Crimp the RJ45 connector
with a crimping tool.
Wire sequence:
Pin 1: White-and-orange
2: Orange
Pin 3: White-and-green
4: Blue
Pin 5: White-and-blue
Pin 6: Green
Pin 7: White-and-brown
Pin 8: Brown
Loosen the swivel nut of the junction box and select an appropriate seal
Step 3
according to cable outer diameter. Lead the cable through the swivel nut,
seal, and junction box successively.
48
33mm
5~6 N.m
Pin
Pin
1 2 3 4 5 6 7 8
Pin 3 and Pin 6 are for
communication connection
RS485- B
RS485+ A
User Manual